Raymond Walkie Pallet Error Code C66 – Forklift Error Codes

Raymond Walkie Pallet Error Code C66


Raymond Pallet Jack

Raymond walkie pallet jack with an error C66 indicate the electric brake coil driver has a shorted or open circuit. The most common problem to look for with this error is a broken wire near the brake coil. The brake coil is located on the drive motor. When the handle is turned, the wiring moves and eventually breaks.

Code DefinitionBrake Coil Driver Open or Shorted
Operator DisplayC66 TA Flash Code “3,2”
System ResponseNo Travel
ReasonThe TA detected an open or short in the Brake Coil Driver2 circuit.
Tests to RunTroubleshoot wiring to and from the brake and the brake coil for opens or shorts.
The brake coil should have approximately 14 ohms resistance.
How to ClearDetermine cause of short or open circuit and correct.

Pinout Matrix

Model ConnectionFunctional DescriptionTheory of Operations NormalNormal LevelVoltage SourceVoltage User
8310
8410
8510
JP1-5Output to BrakeThe TA sends B– to activate the Brake.
Brake coil resistance is approximately 14 Ohms.
Activated:
0V
Deactivated:
B+
TABrake
8310
8410
8510
8610
with Electric Power Steer
JP1-9
Brake Switch
Input
Monitored by the TA to activate the M1 (Main) Contactor. Open between 0 and 10 degrees from vertical or horizontal. The brake (deadman) switch acts to protect against travel while the brake is applied. The handle must be between 10 degrees horizontal and vertical in order for the brake (deadman) to be permitting travel.Switch ON:
11.4VDC
Switch OFF:
0VDC
SW2TA