Crown Error Code 304 – Forklift Error Codes

Crown Error Code 304


Event Code

This the event code 304 for a crown on the SP InfoPoint.

This is the error code 304 for the walkie pallet.

The 304 code is for low battery voltage. Check the emergency disconnect switch for failure, specifically the micro switch on the bottom, if this fails then takes out the main switch. Check all battery connections and fuses.

Admin

Over 20 years of experience on all makes and models material handling equipment. Over 25 years automotive repair.