Drexel Swing Mast Lift Truck Model SLT22/30 Error Codes – Forklift Error Codes

Drexel Swing Mast Lift Truck Model SLT22/30 Error Codes


Drexel Forklift

Error Code 25

This code is only displayed through the handset programming unit. It indicates the 1A contactor is dropping out, or operates too slowly. (See code 46)

Error Code 26

Either 1A or Steering Pump coil driver is shorted and: the corresponding contactor is constantly picked. (Coil driver is in SCR logic card).

Error Codes 27 – 40 Not Used

Error Code 41

SCR unit is overheated

Error Code 42

Motor current sensor malfunction and motor does not run.

Error Code 43

Motor current sensor malfunction and motor does not run.

Error Code 44

SCR 1REC failed to turn off at proper time. May be caused by a shorted 5REC or 2REC (or their snubbers shorted).

Error Code 45

SCR 1REC failed to turn on. May be caused by shorted 2REC (or its snubber shorted) or by defective 1REC.

Error Code 46

SCR 1REC shorted or 1A contactor tips welded.

Error Code 47

SCR 2REC failed to turn on.

Error Code 48

SCR 3REC shorted (or its snubber shorted) or forward or reverse contactor tips welded.

Error Code 49

SCR 5REC did not turn on properly. 5REC or 2REC shorted (or their snubbers shorted) or capacitor circuit open.

Error Code 50

SCR 2REC did not turn on at initial startup 2REC defective or bad connection between 5REC and 2REC.

Error Code 51

Capacitor voltage too high and motor current too high. May be caused by a shorted field or armature winding in motor. If power is being supplied by external “tag” lines, there may be excessive inductance or lack of electrical filtering.

Error Code 52

Capacitor voltage too high and motor current too low. SCR 4REC or its snubber is shorted, or SCR 3REC circuit open. If power is being supplied by external “tag” lines, there may be inductance or lack of electrical filtering.

Error Code 53

SCR 1REC failed to turn off during plugging cycle. Forward or Reverse contactors may be bouncing open when truck is driven over a rough surface or speed bumps. Motor brushes may be improperly seated or motor circuit may be opening. SCR 1REC may be defective.

Error Code 54

Coil driver for forward, reverse, or 1A contactor is shorted. (Drivers are located in SCR logic card).

Error Codes 55 – 56 Not Used

Error Code 57

Voltage across current sensor is wrong polarity. May be caused by an improperly connected battery.

Error Codes 58 – 116 Not Used

Error Code 117

Invalid logic card type in SCR unit (improperly programmed).